Inspection and GD&T
How do you read a micrometer?
Technical review pending. Formulas and values are cited. This notice comes down after a machinist review.
A micrometer reading comes from two scales. The sleeve is the fixed barrel, with a long reference line running along it; the thimble is the part you turn, with numbered lines around its edge.
On an inch micrometer, read the last number the thimble has uncovered on the sleeve at 0.100 in per number, so a 2 is 0.200 in. Add 0.025 in for each short sleeve line showing past that number. Then add the number of the thimble line sitting on the reference line, times 0.001 in. A vernier micrometer adds one more digit in tenths (0.0001 in): the number of the vernier line that lines up exactly with a thimble line.
A metric micrometer reads the same way. Count the whole millimeters above the reference line, and add 0.5 mm if a half-millimeter line below the reference line shows past the last whole millimeter. Then add the number of the thimble line sitting on the reference line, times 0.01 mm.
| Scale | Inch micrometer (in) | Metric micrometer (mm) |
|---|---|---|
| Spindle travel per thimble turn | 0.025 in (40 threads per inch) | 0.5 mm (0.5 mm pitch) |
| Numbered sleeve lines | Every 4th line: 1 = 0.100 in, 2 = 0.200 in | Every 5th line: 0, 5, 10 mm |
| Short sleeve lines | 0.025 in each | 1 mm lines above the reference line; lines below it mark each 0.5 mm halfway point |
| Thimble line on the reference line | Line number x 0.001 in (25 lines per turn) | Line number x 0.01 mm (50 lines per turn) |
| Vernier line that lines up (if fitted) | Line number x 0.0001 in | Line number x 0.001 mm |
Source: Inch values from the US Army and Navy manual TM 9-243, Reading a Standard Micrometer. Metric and vernier values from the open textbook Introduction to Machining, ch. 4.3 by Damon Donner.
How to read an inch micrometer
The spindle has 40 threads per inch, so one turn of the thimble moves it 1/40 in, or 0.025 in. The thimble splits that turn into 25 lines, so each line is 0.001 in, one thou (US Army, Use of Micrometers).
- Read the last number showing on the sleeve. Each number is worth 0.100 in. Example: the 2 is showing, so 0.200 in.
- Count the short lines showing past that number. Each one is 0.025 in. Example: three lines, so 3 x 0.025 = 0.075 in.
- Read the thimble line that sits on the reference line. Each thimble line is 0.001 in. Example: line 1, so 0.001 in.
- Add the three. 0.200 + 0.075 + 0.001 = 0.276 in.
If the reference line falls between two thimble lines, read the lower number. Between 24 and 0, read 24. A plain micrometer stops at the thou here. A vernier micrometer reads the tenths between those two thimble lines.
How to read a micrometer vernier for tenths
A tenth is 0.0001 in, one ten-thousandth. A vernier micrometer adds a scale of ten divisions on the sleeve, running parallel to the reference line.
- Read the thousandths first, using the four steps above. Example: 0.276 in.
- Find the one vernier line that lines up exactly with a thimble line. Only the vernier line's number counts, not which thimble line it meets. Example: vernier line 3.
- Multiply that number by 0.0001 in and add it. 3 x 0.0001 = 0.0003 in, so 0.276 + 0.0003 = 0.2763 in.
If the vernier's 0 line is the one that lines up, there are no tenths to add. The thimble line is sitting right on the reference line.
Only one vernier line can line up at a time because of how the lines are spaced. The 10 spaces between vernier lines cover the same distance as 9 spaces between thimble lines, so each vernier space is 0.0009 in, 0.0001 in shorter than a thimble space (US Army, Reading Vernier Micrometers). Each vernier line along the row sits 0.0001 in further out of step with the thimble lines than the one before it. When the thimble has turned 3 tenths past a thou line, vernier line 3 is the one that lines up.
How to read a metric micrometer
A metric spindle has a 0.5 mm pitch, so one thimble turn moves it 0.5 mm and two turns move it 1 mm (US Army, Reading Metric Micrometers). Whole-millimeter lines sit above the reference line, with every fifth one numbered. The lines below the reference line mark the halfway point between whole millimeters. The thimble has 50 lines, each 0.01 mm (Introduction to Machining, ch. 4.3).
- Count the whole millimeters showing above the reference line. Start at the last numbered line and count the 1 mm lines past it. Example: the 5 is showing with 2 lines past it, so 5 + 2 = 7 mm.
- Check for a half-millimeter line past the last whole millimeter. If one shows below the reference line, add 0.5 mm. Example: one shows, so 7.0 + 0.5 = 7.5 mm.
- Read the thimble line that sits on the reference line. Each line is 0.01 mm. Example: line 28, so 28 x 0.01 = 0.28 mm.
- Add them. 7.5 + 0.28 = 7.78 mm.
A metric vernier micrometer reads to 0.001 mm with the same three vernier steps:
- Read to 0.01 mm first, using the four steps above. Example: 7.78 mm.
- Find the one vernier line that lines up exactly with a thimble line. Example: vernier line 3.
- Multiply that number by 0.001 mm and add it. 3 x 0.001 = 0.003 mm, so 7.78 + 0.003 = 7.783 mm.
Only every second vernier line is numbered on a metric vernier micrometer, so the unmarked line between 2 and 4 is line 3.
If the drawing is in inches, convert the reading with the metric conversion chart for machinists.
How to read a 1-2 inch or larger micrometer
On a 1-2 in micrometer, add 1.000 in to what the sleeve and thimble show (Duke University Pratt student shop). The head reads 0 to 1 in on every frame size, so the frame's starting size goes on top (US Army, Types and Mechanics of Micrometers). Example: a scale reading of 0.276 in is 1.000 + 0.276 = 1.276 in.
Larger micrometers work the same way: add the low end of the frame's range. A 6 in micrometer reads 5 to 6 in, so add 5.000 in (US Navy, Common Types of Micrometers). On a metric micrometer, add the low end of its range the same way.
How much pressure to use on a micrometer
Close the micrometer with the ratchet stop on the end of the thimble, or with the friction thimble, and turn until it slips. Do it the same way for every reading and for the zero check. The ratchet applies a constant measuring pressure (US Army, Types and Mechanics of Micrometers), and a friction thimble slips once enough force reaches the spindle. If your micrometer has neither, close it by feel with light contact and never force it (Quality magazine, Quality 101).
Closing by feel is where readings drift between people. "What feels like solid contact to one operator may not feel correct to another, so the readings will be different," wrote George Schuetz, then Director of Precision Gages at Mahr Inc., in Modern Machine Shop. The Duke student shop gives the accuracy of its friction-thimble 1-2 in micrometer as about ±0.0001 to 0.0002 in, depending on the force on the anvil.
How to check micrometer zero
Check zero before you trust any reading.
- Wipe the anvil and spindle faces with a soft cloth (US Army, Maintenance of Micrometers).
- Close the spindle on the anvil with the ratchet or friction thimble, the same way you measure.
- Read it. A 0-1 in micrometer should read zero.
- On a 1-2 in or larger micrometer, use a setting standard. A setting standard is a gage of known length for this check. Put it between the anvil and spindle and close the spindle on it. A 2 in micrometer uses a 1 in standard and should read 1.000 in (US Army, Methods for Setting Zero).
- Hold a large micrometer in the position you will measure in, vertical or horizontal, when you set it on the standard (Quality 101).
If the reading is off, two types of micrometer reset zero with a small spanner wrench (US Army, Maintenance of Micrometers):
- Rotating-sleeve type: loosen the sleeve's locking nut with the wrench, close the spindle on the anvil, turn the sleeve until its reference line meets the thimble's 0, back the spindle off and tighten the nut (US Army, Methods for Setting Zero).
- Thimble-cap type: back the spindle off, loosen the cap with the wrench, close the spindle on the anvil, hold the spindle still and turn the thimble to 0, then open the spindle and tighten the cap.
Recheck zero after either adjustment. A micrometer that will not give a good zero comes out of service for repair or calibration (Introduction to Machining, ch. 4.3).
A zero check tests the micrometer only at its closed position. To check it at other sizes in its range, close it on a gage block or stack of known size and compare the reading. The gage block stack calculator picks the blocks for a size from a standard 81-piece set.
Common micrometer reading mistakes
- Counting a sleeve line the thimble has not fully uncovered. That error is 0.025 in, or 0.5 mm on a metric micrometer. The thimble tells you whether to count the line, because each sleeve line takes one full thimble turn to uncover. If the thimble reads a low number, the line has only now come out from under the thimble edge: count it. If the thimble reads close to its last line (24 on an inch thimble, 49 on a metric one), the line is still under the edge: do not count it. With the 2 plus three lines showing and the thimble at 24, the reading is 0.200 + 0.075 + 0.024 = 0.299 in. Count the half-hidden fourth line and you would write 0.324 in.
- Missing the half-millimeter line. On a metric micrometer the half-millimeter lines sit on the other side of the reference line from the whole millimeters, so they are easy to skip. That error is 0.5 mm.
- Reading at an angle. Seen from the side, a different thimble line appears to meet the reference line. Look straight at it. If you cannot see it square on the part, lock the spindle and slide the micrometer off to read it.
- Putting the vernier digit in the wrong place. Vernier line 3 adds 0.0003 in, or 0.003 mm on a 0.001 mm metric micrometer. It never adds 0.003 in.
- Measuring over dirt. A chip, lint or oil film on the faces or the part adds its thickness to the reading. Wipe both before you measure.
Does temperature affect micrometer readings?
Temperature changes micrometer readings enough to matter when you read tenths. The reference temperature for dimensional measurement is 20°C (68°F), set by ISO 1. Steel grows about 11.5 µm per meter for each 1°C rise (NIST Engineering Metrology Toolbox).
NIST's example is a 100 mm (about 4 in) steel block at 23°C (73.4°F), which is 3°C (5.4°F) above the reference. It grows about 3.5 µm, or 0.000135 in. That is more than a tenth (0.0001 in).
Heat from your hands moves into the micrometer (Quality magazine, Micrometers: Tools of Choice). After you have handled it, give it time to settle back to room temperature before a tenths reading (NIST Engineering Metrology Toolbox).
Micrometer reading practice with answers
Cover the right column and work each one. Readings 1, 3, 4, 5 and 7 are printed in the sources listed under the table. We built readings 2, 6 and 8 from the same scale values and re-added every sum.
| # | Micrometer | What you see | Reading |
|---|---|---|---|
| 1 | 0-1 in | Sleeve 2 plus 1 line; thimble 16 | 0.200 + 0.025 + 0.016 = 0.241 in |
| 2 | 0-1 in | Sleeve 1 plus 2 lines; thimble 12 | 0.100 + 0.050 + 0.012 = 0.162 in |
| 3 | 0-1 in vernier | Sleeve 2 plus 3 lines; thimble 11; vernier 2 | 0.200 + 0.075 + 0.011 + 0.0002 = 0.2862 in |
| 4 | 0-1 in vernier | Sleeve 2 plus 2 lines; thimble 18; vernier 3 | 0.200 + 0.050 + 0.018 + 0.0003 = 0.2683 in |
| 5 | 1-2 in | Sleeve 4 plus 2 lines; thimble 24 | 1.000 + 0.400 + 0.050 + 0.024 = 1.474 in |
| 6 | Metric | Sleeve 5 mm, half-millimeter line showing; thimble 23 | 5.0 + 0.5 + 0.23 = 5.73 mm |
| 7 | Metric | Sleeve 20 plus 2 lines, no half-millimeter line; thimble 36 | 20 + 2 + 0.36 = 22.36 mm |
| 8 | Metric vernier, 0.001 mm | Reading 6 plus vernier line 2 | 5.73 + 0.002 = 5.732 mm |
Sources: 1 from TM 9-243; 3 from the US Navy vernier micrometer lesson; 4 from Machine Shop VESL; 5 from the Duke student shop; 7 from the US Army vernier micrometer lesson. Readings 2, 6 and 8 use the scale values in Introduction to Machining.
Micrometer FAQ
Do depth and inside micrometers read the same way?
Inside micrometers read the same way as outside micrometers. A depth micrometer's sleeve is numbered in the opposite direction, so the reading grows as the spindle extends farther out of the base (US Navy, NAVEDTRA manuals).
Do I need a micrometer that reads tenths?
A micrometer that reads tenths is not needed for most work. A reading to 0.001 in is acceptable for most applications (US Navy). A vernier micrometer reads to 0.0001 in for closer work (US Army). In metric, a standard micrometer reads to 0.01 mm and a vernier micrometer to 0.001 mm.
FAQ sources: US Navy, inside micrometers; US Navy, Reading a Depth Micrometer; US Navy, Types of Micrometer Calipers; US Army, Reading Vernier Micrometers.
Last updated